Surface Thermometer,Digital Surface Thermometer

KT1310/KT1320 :

Features:

Switchable Resolution 0.1° /1.0 °
Single/Dual Channels with Different Measurements
Data Hold Function

Specification:

Measuring Range -50 ℃ to 1300 ℃; -50 ℉ to 1999 ℉
Sensor K Type thermocouple
Input Single(1310), Dual (1320)
Resolution 50 ℃ to 199.9 ℃...0.1 ℃
-50 ℉ to 199.9 ℉ ...0.1 ℉
(Others-1 ℃/1℉ )
Accuracy 50 ℃ to 199.9℃...0.2% rdg + 1 ℃
-50 ℉ to 199.9 ℉ ...0.2% rdg + 1 ℉
-50 ℃ to 1000 ℃... 0.3% rdg + 1 ℃
-50 ℉ to 1999 ℉ . ..0.3% rdg + 2℉
1000 ℃ to 1300 ℃..0.5% rdg + 1 ℃
(apply to mainframe only at 23℃±5 ℃)
Function H Data Hold & Display ℃/ ℉ selection
0.1 o /1 o resolution selection
T1 & T2 dual points display
T1 - T2 differential
measurement
3-1/2 digit LCD
Overrange 1------
Low Battery BT
Input Protection 60V DC or 24 Vrms AC maximum input
voltage on any combination of input Connector.
Sampling Rate 2.5 times/sec.
Operating Condition 0 ℃ to 50 ℃ (32 ℉ to 122 ℉ ),
0 to 90% R.H. (0 to 35 ℃)
Power Source one 9V battery
Size 135mm(L)x72mm(W)x31mm(H)
Weight 157g
Accessorie Battery & Instruction Manual
* OPTIONAL TEMPERATURE PROBES Model Range(Type K(CA) THERMOCOUPLE)
TP-K01 Bead -50℃ to 200 ℃/-58 ℉ to 392 ℉
General Purpose
TP-K02 Immersion -50 ℃ to 1000 ℃/-58 ℉ to 1832 ℉
Liquid or gels.
TP-K03 Surface -50 ℃ to 750 ℃/-58℉ to 1382 ℉

KT1300、KT1302、KT1303:

Features:

  • Max Hold Function
  • Data Hold Function
  • Aux output JACKS
  • T1-T2 differential measurement

Measuring Range

-50℃ -1300 ℃ ; -50 ℉ -1999 ℉

Sensor

K Type thermocouple

Input

Single(1300), Dual (1302,1303)

Resolution

-50℃ + 199.9℃...0.1℃
-50℉ + 199.9℉...0.1℉
(Others-1℃/1℉)

Accuracy:

-50 ℃ to 199.9 ℃ ...0.3% rdg + 1 ℃
-50 ℉ to 199.9 ℉...0.3% rdg + 2 ℉
-50 ℃ to 1000 ℃ ...0.5% rdg + 1 ℃
-50 ℉ to 1999 ℉F. ..0.5% rdg + 2 ℉
1000 ℃ to 1300 ℃ ..0.75% rdg + 1 ℃
(apply to mainframe only at 23 ℃ +/- 5 ℃ )

Function

H Data Hold & Display ℃ / o F selection
0.1 o /1 o resolution selection
T1 & T2 dual points display
T1 - T2 differential measurement
3-1/2 digit LCD

Temperature Coefficient

Less than 0.1 time the applicable
accuracy specification per ℃ (℉)

Overrange

1------

Low Battery

BT

Temperature Coefficient

Less than 0.1 time the applicable
accuracy specification per ℃ ( ℉)

Input Protection

60V DC or 24 Vrms AC maximum
input voltage on any combination of
input Connector.
Sampling Rate: 2.5 times/sec.

Operating Condition

0 ℃ - 50 ℃ (32 ℉-122 ℉),
0-90% R.H. (0-35 ℃ )

Power Source

one 9V battery

Size Weight

135mm(L)x72mm(W)x31mm(H) & 57g
Accessories: Battery & Instruction Manual

* OPTIONAL TEMPERATURE PROBES

Model Range (Type K (CA)THERMOCOUPLE)
TP-K01 Bead -50 ℃ to 200 ℃ /-58 ℉ to 392 ℉
General Purpose
TP-K02 Immersion -50 ℃ to 1000 ℃ /-58℉ to 1832 ℉
Liquid or gels.
TP-K03 Surface -50 ℃ to 750 ℃ /-58℉ to 1382 ℉