Digital Ultrasonic Flaw Detector FD500B:

Digital Ultrasonic Flaw Detector

Display
Hi-resolution (320×240 pixels) multi-color TFT  LCD with 4 user-selectable
brightness control provides high contrast viewing of the waveform from bright,
direct sunlight to complete darkness.
The hi-resolution multi-color TFT LCD display with fast 60 Hz update gives an
“analog look” to the waveform providing detailed information that is critical in
many applications including nuclear power plant inspections.  
Range
Up to 9999 mm in steel. suitable for use on large work pieces and in
high-resolution measurements.
Pulser
Pulse Energy selectable among Low, Medium and High.
Pulse Width tunable from 0.1µs to 0.5 µs to match the probes with different
frequency.
Pulse Repetition Frequency adjustable from 10 Hz to 1 KHz in 1 Hz increments.  
Damping selectable among 100Ω、200Ω and 400Ω for optimum probe
performance
Test Modes include Pulse echo, dual and thru-transmission  
Receiver
Sampling:10 digit AD Converter at the sampling speed of 160 MHz  
Rectification:Positive Halfwave, Negative Halfwave, Fullwave and RF
Analog Bandwidth: 0.5MHz to 15MHz  capability with selectable frequency
ranges (automatically set by the instrument) to match probe for optimum
performance.
Gain:0 dB to 110 dB adjustable in selectable steps 0.1 dB, 2 dB, 6 dB, and locked.

Gates
Gate Start: Variable over entire displayed range
Gate Width: Variable from Gate Start to end of displayed range
Gate Height: Variable from 0 to 99% Full Screen Height
Alarms: Threshold positive/negative
Memory
Memory of 100 channel files to store calibration set-ups
Memory of 1000 wave files to store A-Scan patterns and instrument settings.
All the files can be stored, recalled and cleared.

Functions
Semiautomatic two point calibration:  Automated calibration of transducer zero offset and/or material velocity
Flaw Locating:Live display Sound-path, Projection (surface distance),
Depth, Amplitude,  
Flaw sizing: Automatic flaw sizing using AVG/AVG or DAC, speeds reporting of defect acceptance or rejection.
Digital Readout and Trig. Function:  Thickness/Depth can be displayed in digital readout when using a normal probe and Peam path, Surface Distance and Depth are directly displayed when angle probe is in use.
Both the DAC and the AVG method of amplitude evaluation are available.
Curved Surface Correction feature
Crack Height Measure function
Weld figure feature
Magnify gate:spreading of the gate range over the entire screen width Video Recording and play Auto-gain function 
Envelope: Simultaneous display of  live A-scan at 60 Hz update rate and envelope of A-scan display
Peak Hold: Compare frozen peak waveforms to live A-Scans to easily interpret test results.
A Scan Freeze:Display freeze holds waveform and sound path data B Scan display feature
Real Time Clock 

The instrument clock keeps running tracking the time.
Communication
High speed USB2.0 port.
The optional DataPro software helps manage and format stored inspection data for high-speed transfer to the PC. Data  can be printed or easily copied and pasted into word processing files and spreadsheets for further reporting needs. New features include live screen capture mode and database tracking. 

Battery
Internal rechargeable Li-ion battery pack rated 7.2V at 8800 mAh  
8 hours nominal operating time depending on display brightness
8-10 hours typical recharge time
Knob
Operating adjustments are easily and quickly made using the rotary knob. 

Specifications

Range: 0 to 9999 mm, at steel velocity
Material Velocity: 1000 to 9999m/s
Display Delay: -20 to 3400 µs
Probe Delay/Zero Offset : 0 to 99.99µs 
Sensitivity: 110 dB max in selectable  resolution 0.1, 1.0, 2.0, 6.0 dB and locked.
Test Modes: Pulse echo, dual element and thru-transmission
Pulser: Tunable Square Wave Pulser
Pulse Repetition Frequency ranges from 10 Hz to 1000 Hz
Pulse Energy: Low, Medium and High
Damping: 100, 200, 400 ohms
Bandwidth (amplifier bandpass ): 0.5 to 15 MHz
Gate Monitors: Two independent gates controllable over entire sweep range
Rectification: Positive halfwave, negative halfwave, fullwave, RF
System Linearity: Horizontal: +/-0.2% FSW, Vertical: 0.25% FSH, Amplifier
Accuracy +/-1 dB. 
Reject (suppression): 0 to 80% full screen height
Units: Inch or millimeter
Transducer Connections: BNC or LEMO 
Power Requirements: AC Mains 100-240 VAC, 50-60 Hz
Dimensions: 263H×170W×61D mm
Operating Temperature: -10℃ to 50℃
Storage Temperature: -30℃ to 50℃

Digital Ultrasonic Flaw Detector FD510B:

Digital Flaw Detector

Display
Hi-resolution (320×240 pixels) bright EL Display with 4 user-selectable
brightness control provides high contrast viewing of the waveform from bright, direct sunlight to complete darkness.
The hi-resolution EL display with fast 60 Hz update gives an “analog look” to the waveform providing detailed information that is critical in many applications including nuclear power plant inspections.  
Range
Up to 9999 mm in steel. suitable for use on large work pieces and in
high-resolution measurements.
Pulser
Pulse Energy selectable among Low, Medium and High.
Pulse Width tunable from 0.1µs to 0.5 µs to match the probes with different frequency.
Pulse Repetition Frequency adjustable from 10 Hz to 1 KHz in 1 Hz increments.  
Damping selectable among 100Ω、200Ω and 400Ω for optimum probe
performance
Test Modes include Pulse echo, dual and thru-transmission  

Receiver
Sampling:10 digit AD Converter at the sampling speed of 160 MHz  
Rectification:Positive Halfwave, Negative Halfwave, Fullwave and RF
Analog Bandwidth: 0.5MHz to 15MHz  capability with selectable frequency ranges (automatically set by the instrument) to match probe for optimum performance.
Gain:0 dB to 110 dB adjustable in selectable steps 0.1 dB, 2 dB, 6 dB, and locked.

Gates
Two fully independent gates offer a range  of measurement options for signal height or distance using peak triggering.  
The echo-to-echo mode allows accurate gate positioning for signals which are extremely close together.
Gate Start: Variable over entire displayed range
Gate Width: Variable from Gate Start to end of displayed range
Gate Height: Variable from 0 to 99% Full Screen Height
Alarms: Threshold positive/negative
Memory
Memory of 100 channel files to store calibration set-ups
Memory of 1000 wave files to store A-Scan patterns and instrument settings.
All the files can be stored, recalled and cleared.

Functions
Semiautomatic two point calibration:  Automated calibration of transducer
zero offset and/or material velocity
Flaw Locating:Live display Sound-path, Projection (surface distance),
Depth, Amplitude,  
Flaw sizing: Automatic flaw sizing using AVG/AVG or DAC, speeds reporting of defect acceptance or rejection.
Digital Readout and Trig. Function:  Thickness/Depth can be displayed in
digital readout when using a normal probe and Peam path, Surface
Distance and Depth are directly displayed when angle probe is in use. 
Both the DAC and the AVG method of amplitude evaluation are available.
Curved Surface Correction feature
Crack Height Measure function
Weld figure feature
Magnify gate:spreading of the gate range over the entire screen width
Video Recording and play
Auto-gain function
Envelope: Simultaneous display of  live A-scan at 60 Hz update rate and
envelope of A-scan display
Peak Hold: Compare frozen peak waveforms to live A-Scans to easily
interpret test results.
A Scan Freeze:Display freeze holds waveform and sound path data
B Scan display feature

Real Time Clock
The instrument clock keeps running tracking the time.
Communication
High speed USB2.0 port.
The optional DataPro software helps manage and format stored inspection data for high-speed transfer to the PC. Data  can be printed or easily copied and pasted into word processing files and spreadsheets for further reporting needs. New features include live screen capture mode and database tracking.

Battery
Internal rechargeable Li-ion battery pack rated 7.2V at 8800 mAh  
8 hours nominal operating time depending on display brightness
8-10 hours typical recharge time
Knob
Operating adjustments are easily and quickly made using the rotary knob.

Range: 0 to 9999 mm, at steel velocity
Material Velocity: 1000 to 9999m/s
Display Delay: -20 to 3400 µs
Probe Delay/Zero Offset : 0 to 99.99µs
Sensitivity: 110 dB max in selectable  resolution 0.1, 1.0, 2.0, 6.0 dB and locked.

Specifications
Test Modes: Pulse echo, dual element and thru-transmission 
Pulser: Tunable Square Wave Pulser
Pulse Repetition Frequency ranges from 10 Hz to 1000 Hz
Pulse Energy: Low, Medium and High
Damping: 100, 200, 400 ohms
Bandwidth (amplifier bandpass ): 0.5 to 15 MHz
Gate Monitors: Two independent gates controllable over entire sweep range 
Rectification: Positive halfwave, negative halfwave, fullwave, RF
System Linearity: Horizontal: +/-0.2% FSW, Vertical: 0.25% FSH, Amplifier
Accuracy +/-1 dB. 
Reject (suppression): 0 to 80% full screen height
Units: Inch or millimeter 
Transducer Connections: BNC or LEMO
Power Requirements: AC Mains 100-240 VAC, 50-60 Hz
Dimensions: 263H×170W×61D mm
Operating Temperature: -10℃ to 50℃
Storage Temperature: -30℃ to 50℃

Digital Ultrasonic Flaw Detector FD350B:

Portable Digital Ultrasonic Flaw Detector

Display :
Hi-resolution (320×240 pixels) multi-color TFT  LCD with 4 user-selectable brightness control provides high contrast viewing of the waveform from bright, direct sunlight to complete darkness.
The hi-resolution multi-color TFT LCD display with fast 60 Hz update gives an “analog look” to the waveform providing detailed information that is critical in many applications including nuclear power plant inspections.  

Range :
Up to 6000 mm in steel. suitable for use on large work pieces and in
high-resolution measurements.
Pulser :
Pulse Energy selectable among Low, Medium and High.
Pulse Repetition Frequency adjustable from 10 Hz to 1 KHz in 1 Hz increments.  
Damping selectable among 100Ω、200Ω and 400Ω for optimum probe
performance
Test Modes include Pulse echo, dual and thru-transmission  

Receiver :
Sampling:10 digit AD Converter at the sampling speed of 160 MHz  
Rectification:Positive Halfwave, Negative Halfwave, Fullwave and RF
Analog Bandwidth: 0.5MHz to 10MHz  capability with selectable frequency
ranges (automatically set by the instrument) to match probe for optimum
performance.
Gain:0 dB to 110 dB adjustable in selectable steps 0.1 dB, 2 dB, 6 dB, and locked.

Gates :
Two fully independent gates offer a range  of measurement options for signal height or distance using peak triggering.  
The echo-to-echo mode allows accurate gate positioning for signals which are extremely close together.
Gate Start: Variable over entire displayed range
Gate Width: Variable from Gate Start to end of displayed range
Gate Height: Variable from 0 to 99% Full Screen Height
Alarms: Threshold positive/negative
Memory :
Memory of 100 channel files to store calibration set-ups
Memory of 1000 wave files to store A-Scan patterns and instrument settings.
All the files can be stored, recalled and cleared.
Functions :
Semiautomatic two point calibration:  Automated calibration of transducer
zero offset and/or material velocity
Flaw Locating:Live display Sound-path, Projection (surface distance),
Depth, Amplitude,  
Flaw sizing: Automatic flaw sizing using AVG/AVG or DAC, speeds reporting of defect acceptance or rejection.
  Digital Readout and Trig. Function:  Thickness/Depth can be displayed in
digital readout when using a normal probe and Peam path, Surface
Distance and Depth are directly displayed when angle probe is in use.
  Both the DAC and the AVG method of amplitude evaluation are available.
  Curved Surface Correction feature
  Crack Height Measure function
  Weld figure feature
  Magnify gate:spreading of the gate range over the entire screen width
  Video Recording and play
  Auto-gain function
  Envelope: Simultaneous display of  live A-scan at 60 Hz update rate and
envelope of A-scan display
  Peak Hold: Compare frozen peak waveforms to live A-Scans to easily
interpret test results.
  A Scan Freeze:Display freeze holds waveform and sound path data
  B Scan display feature

Real Time Clock
The instrument clock keeps running tracking the time.
Communication
High speed USB2.0 port.
The optional DataPro software helps manage and format stored inspection data for high-speed transfer to the PC. Data  can be printed or easily copied and pasted into word processing files and spreadsheets for further reporting needs. New features include live screen capture mode and database tracking.

Battery
Internal rechargeable Li-ion battery pack rated 7.2V at 8800 mAh  
8 hours nominal operating time depending on display brightness
8-10 hours typical recharge time
Knob
Operating adjustments are easily and quickly made using the rotary knob.

Specifications
Range: 0 to 6000 mm, at steel velocity
Material Velocity: 1000 to 9999m/s
Display Delay: -20 to 3400 µs 
Probe Delay/Zero Offset : 0 to 99.99µs
Sensitivity: 110 dB max in selectable  resolution 0.1, 1.0, 2.0, 6.0 dB and
locked.
Test Modes: Pulse echo, dual element and thru-transmission
Pulse Repetition Frequency ranges from 10 Hz to 1000 Hz 
Pulse Energy: Low, Medium and High spike pulse.
Damping: 100, 200, 400 ohms
Bandwidth (amplifier bandpass ): 0.5 to 10 MHz
Gate Monitors: Two independent gates controllable over entire sweep range
Rectification: Positive halfwave, negative halfwave, fullwave, RF
System Linearity: Horizontal: +/-0.2% FSW, Vertical: 0.25% FSH, Amplifier
Accuracy +/-1 dB.
Reject (suppression): 0 to 80% full screen height
Units: Inch or millimeter
Transducer Connections: BNC or LEMO
Power Requirements: AC Mains 100-240 VAC, 50-60 Hz
Dimensions: 263H×170W×61D mm 
Operating Temperature: -10℃ to 50℃
Storage Temperature: -30℃ to 50℃

Digital Ultrasonic Flaw Detector FD800B:

Ultrasonic Flaw Detector

Functions

  1. l        Semiautomatic two point calibration: Automated calibration of transducer zero offset and/or material velocity
  2. l        Flaw LocatingLive display Sound-path, Projection (surface distance), Depth, Amplitude,
  3. l        Flaw sizing: Automatic flaw sizing using AVG/AVG or DAC, speeds reporting of defect acceptance or rejection.
  4. l        Digital Readout and Trig. Function: Thickness/Depth can be displayed in digital readout when using a normal probe and Peam path, Surface Distance and Depth are directly displayed when angle probe is in use.
  5. l        Both the DAC and the AVG method of amplitude evaluation are available.
  6. l        TVG(Time Varied Gain).
  7. l        AWS D1.1.
  8. l        Curved Surface Correction feature
  9. l        Crack Height Measure function
  10. l        Weld figure feature
  11. l        Magnify gatespreading of the gate range over the entire screen width
  12. l        Video Recording and play
  13. l        Auto-gain function
  14. l        Envelope: Simultaneous display of live A-scan at 60 Hz update rate and envelope of A-scan display
  15. l        Peak Hold: Compare frozen peak waveforms to live A-Scans to easily interpret test results.
  16. l        A Scan FreezeDisplay freeze holds waveform and sound path data
  17. l        B Scan display feature
  18.  

Specifications

  1. l        Range: 0 to 9999 mm, at steel velocity
  2. l        Material Velocity: 1000 to 9999m/s
  3. l        Display Delay: -20 to 3400 µs
  4. l        Probe Delay/Zero Offset : 0 to 99.99µs
  5. l        Sensitivity: 110 dB max in selectable resolution 0.1, 1.0, 2.0, 6.0 dB and locked.
  6. l        Test Modes: Pulse echo, dual element and thru-transmission
  7. l        Pulser: Tunable Square Wave Pulser
  8. l        Pulse Repetition Frequency ranges from 10 Hz to 1000 Hz
  9. l        Pulse Energy: Low, Medium and High
  10. l        Damping: 100, 200, 400 ohms
  11. l        Bandwidth (amplifier bandpass ): 0.5 to 15 MHz
  12. l        Gate Monitors: Two independent gates controllable over entire sweep range
  13. l        Rectification: Positive halfwave, negative halfwave, fullwave, RF
  14. l        System Linearity: Horizontal: +/-0.2% FSW, Vertical: 0.25% FSH, Amplifier Accuracy +/-1 dB.
  15. l        Reject (suppression): 0 to 80% full screen height
  16. l        Units: Inch or millimeter
  17. l        Transducer Connections: BNC or LEMO
  18. l        Power Requirements: AC Mains 100-240 VAC, 50-60 Hz
  19. l        Operating Temperature: -10℃ to 50℃
  20. l        Storage Temperature: -30℃ to 50℃

 